OVTS Special Wire-Rope Isolators
OVTS-400 Special Vibration Isolators
OVTS-400 vibration isolator with a Z-direction rated load of 4000 N and Z-direction static stiffness of 418 N/mm. Review directional specifications and mounting requirements for your equipment.

- Z rated load (N)
- 4000
- Z static stiffness (N/mm)
- 418
- Z deflection at rated load (mm)
- 10±2
- Weight (kg)
- 7.5
Model specifications
Performance and key specifications
- Weight (kg)
- 7.5
- Z maximum allowed deflection (mm)
- 38
- Z static stiffness (N/mm)
- 418
- Z natural frequency (Hz)
- 8±2
- Z rated load (N)
- 4000
- Z shock stiffness (N/mm)
- 476
- Dynamic stiffness · Z (N/mm)
- 1418
- Z deflection at rated load (mm)
- 10±2
- Damping ratio (C/Cc)
- ≥0.18
X / Y direction specifications
- Y static stiffness (N/mm)
- 279
- X deflection at rated load (mm)
- 10±2
- X natural frequency (Hz)
- 8±2
- X rated load (N)
- 1880
- Y deflection at rated load (mm)
- 10±2
- Y natural frequency (Hz)
- 8±2
- Dynamic stiffness · Y (N/mm)
- 570
- X shock stiffness (N/mm)
- 205
- X maximum allowed deflection (mm)
- 40
- X static stiffness (N/mm)
- 279
- Dynamic stiffness · X (N/mm)
- 570
- Y shock stiffness (N/mm)
- 205
- Y maximum allowed deflection (mm)
- 40
- Y rated load (N)
- 1880
Selection and installation
Check the Z, X and Y direction loads, deflections and natural frequencies separately. Static, dynamic and shock stiffness are not interchangeable. Provide equipment mass, support layout, excitation frequency and allowable travel to confirm the mounting configuration.
Series working principle
Stranded steel cable deforms between mounting bars. Friction between the strands dissipates energy; stiffness varies with displacement and load direction.
Continuous vibration or transport shock?
Use a vibration-isolation review for pumps, cabinets and transported equipment. The motion-sizing calculator covers supported end-stop shock absorber cases; it does not calculate isolation performance.
I only know the equipment weight. Can I start?
Yes. Send the weight, support layout, equipment type and any photos or test report. Mark frequency or shock data as unknown; engineering review must establish them before a performance claim can be made.
Can I divide the total weight by four mounts?
Only a symmetric layout with a centered center of gravity and the corresponding static assumptions supports equal sharing. An offset center of gravity, torque or transport acceleration can produce unequal loads. Supply support positions and the center of gravity, or mark it unknown.
Rubber or wire rope isolators?
Compare the required frequency range, load direction, allowable displacement, damping and environment. Neither material is universally better. Directional load and stiffness data, shock conditions and durability requirements determine the candidate.
Unknown data is welcome: say what is measured, estimated or not yet known. Photos, drawings and existing test records help define the next checks.
Send an isolation briefDrawings and documents
Open approved PDFs without signing in. Sign in for DWG and STEP files; request formats that are not yet approved.
Specification sources
Specifications follow the current model catalogue, supported by the referenced catalogue pages and the product database model record.
- Vibration isolator catalogue (Chinese, 2024) · pp. 54, 55
- Product database: corresponding model record