How to Use Shock Absorber Selection Curves
What catalog selection curves mean and how they support model or adjustment-setting checks.
直接回答
Selection curves compare impact velocity with total energy for a model or adjustment setting. A point outside the allowed curve means the absorber may be overloaded; for adjustable models, the usable setting range is limited by the impact velocity and damping curve.
本页回答的问题
- How do I use industrial shock absorber selection curves?
- What does total energy vs impact velocity mean?
- How do I set an adjustable shock absorber?
所需输入
totalEnergyNmimpactVelocityMpsmodelSeriesadjustmentSetting
计算步骤
- 1
Locate impact velocity
Find the velocity value on the model or setting curve.
- 2
Locate total energy
Find the calculated total energy per cycle and compare it with the curve boundary.
- 3
Stay inside the curve
Choose a model or adjustment range where the velocity-energy point sits inside the safe operating envelope.
常见错误
- Reading only energy and ignoring velocity.
- Using an adjustment setting beyond the velocity limit.
- Using selection curves as a replacement for energy-per-hour checks.
目录来源说明
- The full product catalog p.18 explains adjustable setting range by shock velocity and damping curves; p.28, p.29 and p.34 show EN selection curves using total energy and impact velocity.
从答案进入型号 shortlist。
已有输入参数时可使用选型工具,也可以发送应用数据做工程复核。