每小时能量计算

How to Check Energy per Hour for Shock Absorber Selection

Why the same absorber can pass single-impact energy but fail under high cycle frequency.

直接回答

Energy per hour is the calculated energy per cycle multiplied by the number of impacts per hour. The selected model must satisfy both energy per cycle and energy per hour ratings, because repeated impacts create heat and duty-cycle limits.

本页回答的问题

  • How do I calculate energy per hour for a shock absorber?
  • Why does cycle rate matter for shock absorber selection?
  • Can a shock absorber pass energy per cycle but fail in continuous operation?

所需输入

energyPerCycleNmcyclesPerHourambientTemperaturecoolingCondition

公式逻辑

Energy per hour

E is absorbed energy per cycle. ETC is the hourly energy load that must stay within the catalog rating.

ETC = E x cyclesPerHour

单位: N m/h

计算步骤

  1. 1

    Calculate energy per cycle

    Start with the total stopping energy required for one impact.

  2. 2

    Multiply by cycle rate

    Multiply by the expected number of impacts per hour under normal operation.

  3. 3

    Check heat-duty capacity

    Compare the result with the catalog energy-per-hour rating, then review high-frequency families when needed.

常见错误

  • Selecting only by maximum energy per impact.
  • Using ideal cycle rate instead of maximum production cycle rate.
  • Ignoring hot environments that reduce thermal margin.

目录来源说明

  • The full product catalog tables list both maximum energy per cycle (ET) and energy per hour (ETC), which makes this an answerable calculation topic.

从答案进入型号 shortlist。

已有输入参数时可使用选型工具,也可以发送应用数据做工程复核。

How to Check Energy per Hour for Shock Absorber Selection