6JX Series
6JX Enclosed Rubber Mounts
Enclosed mounts with a protective connection and a nonlinear load–deflection characteristic.
Catalog and inquiry series
Technical model table
18 of 18 models
Columns5
Choose up to 8 table columns
- Request a quote
6JX-25
- Natural frequency (Hz)
- 7±1.5
- Weight (kg)
- 1.00
- Damping ratio (C/Cc)
- 0.04~0.06
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-25N
- Natural frequency (Hz)
- 8±1.5
- Weight (kg)
- —
- Damping ratio (C/Cc)
- 0.06~0.10
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-45
- Natural frequency (Hz)
- 7±1.5
- Weight (kg)
- 1.05
- Damping ratio (C/Cc)
- 0.04~0.06
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-45N
- Natural frequency (Hz)
- 8±1.5
- Weight (kg)
- —
- Damping ratio (C/Cc)
- 0.06~0.10
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-70
- Natural frequency (Hz)
- 7±1.5
- Weight (kg)
- 1.26
- Damping ratio (C/Cc)
- 0.04~0.06
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-70N
- Natural frequency (Hz)
- 8±1.5
- Weight (kg)
- —
- Damping ratio (C/Cc)
- 0.06~0.10
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-100
- Natural frequency (Hz)
- 7±1.5
- Weight (kg)
- 1.36
- Damping ratio (C/Cc)
- 0.04~0.06
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-100N
- Natural frequency (Hz)
- 8±1.5
- Weight (kg)
- —
- Damping ratio (C/Cc)
- 0.06~0.10
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-200
- Natural frequency (Hz)
- 7±1.5
- Weight (kg)
- 1.90
- Damping ratio (C/Cc)
- 0.04~0.06
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-200N
- Natural frequency (Hz)
- 8±1.5
- Weight (kg)
- —
- Damping ratio (C/Cc)
- 0.06~0.10
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-400
- Natural frequency (Hz)
- 7±1.5
- Weight (kg)
- 7.30
- Damping ratio (C/Cc)
- 0.04~0.06
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-400N
- Natural frequency (Hz)
- 8±1.5
- Weight (kg)
- —
- Damping ratio (C/Cc)
- 0.06~0.10
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-600
- Natural frequency (Hz)
- 7±1.5
- Weight (kg)
- 9.00
- Damping ratio (C/Cc)
- 0.04~0.06
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-600N
- Natural frequency (Hz)
- 8±1.5
- Weight (kg)
- —
- Damping ratio (C/Cc)
- 0.06~0.10
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-900
- Natural frequency (Hz)
- 6±1.5
- Weight (kg)
- 12.50
- Damping ratio (C/Cc)
- 0.05~0.08
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-900N
- Natural frequency (Hz)
- 8±1
- Weight (kg)
- —
- Damping ratio (C/Cc)
- 0.08~0.12
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-1200
- Natural frequency (Hz)
- 6±1.5
- Weight (kg)
- 21.0
- Damping ratio (C/Cc)
- 0.05~0.08
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
- Request a quote
6JX-1200N
- Natural frequency (Hz)
- 8±1
- Weight (kg)
- —
- Damping ratio (C/Cc)
- 0.08~0.12
- X maximum allowed deflection (mm)
- 3
- Y maximum allowed deflection (mm)
- 3
Construction and operating principle
An elastomer supports the equipment and reduces vibration transmission through controlled deformation and material damping. Load direction and static deflection determine the installation choice.
Applications and selection
Pumps, fans, compressors, diesel engines and auxiliary equipment. Confirm the operating temperature, media exposure and static load per mount.